S7-300
Overview
S7-300
• The modular mini PLC system for the low and mid-performance ranges
• With comprehensive range of modules for optimum adaptation to the automation task
• Flexible use through simple implementation of distributed structures and versatile networking
• User-friendly handling and uncomplicated design without a fan
• Can be expanded without problems when the tasks increase
• Powerful thanks to a range of integrated functions
S7-300F
• Failsafe automation system for plants with increased safety requirements for production technology
• Based on S7-300
• Additional ET 200S and ET 200M distributed I/O stations complete with safety-related modules can be connected
• Safety-related communication via PROFIBUS DP with PROFIsafe profile
• Standard modules can be used in addition for non-safety-relevant applications
Application
S7-300
The SIMATIC S7-300 is the modular mini PLC system for the low-end and mid performance ranges.
The modular and fan-free design, simple implementation of distributed structures, and convenient handling make the SIMATIC S7-300 the cost-effective and user-friendly solution for the most diverse tasks in the low-end and mid performance ranges.
Application areas of the SIMATIC S7-300 include:
• Special machinery,
• Textile machinery,
• Packaging machinery,
• General mechanical equipment manufacture,
• Controller building,
• Machine tool manufacture,
• Installation systems,
• Electrical/electronics industry and the skilled trades.
Several performance-graded CPUs and a comprehensive range of modules with a host of user-friendly functions allow you to use only those modules necessary for your application. In the case of task expansions, the controller can be upgraded at any time by means of additional modules.
The SIMATIC S7-300 is universal in use:
• Maximum suitability for industry thanks to high electromagnetic compatibility and high resistance to shock and vibration.
S7-300F
The SIMATIC S7-300F fail-safe automation system is used in plants with increased safety requirements. It controls processes where immediate shutdown presents no danger to personnel or the environment.
The S7-300F meets the following safety requirements:
• Requirement class AK 1 to AK 6 in accordance with DIN V 19250/DIN V VDE 0801
• Safety requirement class SIL 1 to SIL 3 in accordance with IEC 61508
• Category 1 to 4 in accordance with EN 954-1
In addition, standard modules can be used in the S7-300F as well as the fail-safe modules. This makes it possible to establish a fully integrated control system for a plant where non-safety related tasks and safety-related tasks co-exist. The overall plant is configured and programmed with the same standard tools.
Product Range
Standard CPUs
• CPU 312 for small plants
• CPU 314 for plants with additional requirements on the program scope and the instruction processing speed
• CPU 315-2 DP for plants with medium to high requirements on the program scope and distributed configuration using PROFIBUS DP
• CPU 315-2 PN/DP for plants with medium to high requirements on the program scope and distributed configuration using PROFIBUS DP and PROFINET IO; these can be implemented as distributed intelligence in Component Based Automation (CBA) on PROFINET
• CPU 317-2 DP for plants with high requirements on the program scope and distributed configuration using PROFIBUS DP
• CPU 317-2 PN/DP for plants with high requirements on the program scope and distributed configuration using PROFIBUS DP and PROFINET IO; these can be implemented as distributed intelligence in Component Based Automation (CBA) on PROFINET
• CPU 319-3 PN/DP for plants with very high requirements on the program scope and networking as well as distributed configuration using PROFIBUS DP and PROFINET IO; these can be implemented as distributed intelligence in Component Based Automation (CBA) on PROFINET
Compact CPUs
• CPU 312C, the compact CPU with integrated digital inputs/outputs and integrated counting function
• CPU 313C, the compact CPU with integrated digital and analog inputs and outputs
• CPU 313C-2 PtP, the compact CPU with integrated digital inputs/outputs, second serial port and integrated counting function
• CPU 313C-2 DP, the compact CPU with integrated digital inputs/outputs, PROFIBUS-DP port and integrated counting function
• CPU 314C-2 PtP, the compact CPU with integrated digital and analog inputs/outputs, second serial port and integrated counting and
positioning functions
• CPU 314C-2 DP, the compact CPU with integrated digital and analog inputs/outputs, PROFIBUS-DP port and integrated counting and positioning functions
• CPU 314C-2 PN/DP, the compact CPU with integrated digital and analog inputs/outputs and the integrated counting and positioning functions;
with the option of a distributed topology via PROFIBUS DP and PROFINET IO;
can be implemented as distributed intelligence in Component Based Automation (CBA) on PROFINET
Technology CPUs
• CPU 315T-2 DP for plants with medium to high requirements on program scope and distributed configuration using PROFIBUS DP, which also require regulated motion control of up to 8 axes
• CPU 317T-2 DP for plants with high requirements on program scope and distributed configuration using PROFIBUS DP, which must handle simultaneous motion control tasks
• CPU 317TF-2 DP for plants with high requirements on program scope and distributed configuration using PROFIBUS DP, which must handle simultaneous motion control and safety tasks
Failsafe CPUs
• CPU 315F-2 DP for failsafe plants with medium to high requirements on the program scope and distributed configuration using
PROFIBUS DP
• CPU 315F-2 PN/DP for failsafe plants with medium to high requirements on the program scope and distributed configuration using PROFIBUS DP and PROFINET IO; these can be implemented as distributed intelligence in Component Based Automation (CBA) on PROFINET
• CPU 317F-2 DP for failsafe plants with high requirements on the program scope and distributed configuration using PROFIBUS DP
• CPU 317F-2 PN/DP for failsafe plants with high requirements on the program scope and distributed configuration using PROFIBUS DP and PROFINET IO; these can be implemented as distributed intelligence in Component Based Automation (CBA) on PROFINET
• CPU 319F-3 PN/DP for fail-safe plants with very high requirements on the program scope and distributed configuration using PROFIBUS DP and PROFINET IO; these can be implemented as distributed intelligence in Component Based Automation (CBA) on PROFINET