S7-1500
Overview
• Modular, scalable, and universally usable system in IP20 level of protection
• The system solution for a variety of automation applications in discrete automation
• Highest performance with excellent usability
• Configurable exclusively in the Totally Integrated Automation Portal with STEP 7 Professional V12 or higher
Performance
• Increase in performance through
o Faster command execution
o Language extensions
o New data types
o Faster backplane bus
o Optimized code generation
• Powerful communication:
o PROFINET IO (2-port switch) as standard interface;
from CPU 1515-2 PN, one or more additional integrated PROFINET interfaces, e.g. for network separation
o Expandable with communication modules for bus systems and point-to-point connection
Integrated technology
• Motion Control integrated without additional modules:
o Standardized blocks (PLCopen) for connection of analog and PROFIdrive-capable drives
o The Motion Control functionality supports speed-controlled and positioning axes as well as external encoders
o Positionally precise gearing between axes
• Comprehensive trace functions for all CPU tags for real-time diagnosis and sporadic error detection;
for effective commissioning and quick optimization of drives and controls
• Comprehensive control functionalities:
e.g. easily configurable blocks for automatic optimization of the control parameters for optimum control quality
• Additional functions through available technology modules:
e.g. high-speed counting, position detection, or measurement functions for signals up to 1 MHz
Safety Integrated
Protection of personnel and machinery – within the framework of an integrated complete system
• Failsafe SIMATIC S7-1500F controllers for processing standard and safety programs on the same controller.
Generation of the failsafe and standard user program is carried out in the TIA Portal with the same editors; this enables failsafe data to be evaluated like standard data in the standard user program, for example. Due to this integration the system benefits and the comprehensive functionality of SIMATIC are also available for failsafe applications
Security Integrated
• Password-based know-how protection against unauthorized reading and modification of program blocks
• Copy protection for greater protection against unauthorized copying of program blocks:
With copy protection, individual blocks on the SIMATIC memory card can be tied to its serial number so that the block can only be run if the configured memory card is inserted into the CPU.
• Rights concept with four different authorization levels:
Different access rights can be assigned to various user groups. The new protection level 4 makes it possible to also restrict communication to HMI devices.
• Improved manipulation protection:
Changed or unauthorized transfers of engineering data are detected by the controller.
• For use of an Ethernet CP (CP 1543-1):
o Additional access protection by means of a firewall
o Setup of secure VPN connections (V12 SP1 or higher)
Design and handling
• CPUs with display for plain text information:
o Information about article numbers, firmware version, and the serial number of all connected modules can be displayed
o Setting the IP address of the CPU and additional network settings directly on site, without programming device
o Display of occurring error messages directly as plain text message, meaning reduction in downtime
• Uniform front connectors for all modules and integrated potential bridges for flexible potential group formation simplify stock keeping and reduce wiring costs
• Integrated DIN rail in the S7-1500 mounting rail:
quick and easy installation of additional components such as miniature circuit breakers, relays, etc.
• Central expansion with signal modules:
for flexible adaptation to any application
• System cabling for digital signal modules:
for fast and clearly arranged connecting to sensors and actuators in the field and simple wiring inside the control cabinet
• Power supply:
o Load power supply modules (PMs) for supplying the module with 24 V
o Power supply modules to supply power to the internal module electronics via the backplane bus
• Distributed expansion:
o Use of up to 30 signal modules, communication modules, and technology modules via the PROFINET interface module IM 155-5 for the ET 200MP I/O system
o No difference in terms of handling and system functions in central and distributed operation
Integrated system diagnostics
• Integrated system diagnostics for CPUs, activated by default:
o Consistent plain text display of system diagnostic information in the display, TIA Portal, HMI, and web server, even for drive messages. Messages are updated even if the CPU is in STOP state.
o System diagnostics integrated in the CPU firmware. Configuration by user not required. The diagnostics is automatically updated on configuration changes.
Application
The SIMATIC S7-1500 is the modular control system for a variety of automation applications in discrete automation.
The modular and fan-free design, simple implementation of distributed structures, and convenient handling make the SIMATIC S7-1500 the cost-effective and user-friendly solution for the most diverse tasks.
Application areas of the SIMATIC S7-1500 include:
• Special machinery
• Textile machinery
• Packaging machinery
• General mechanical engineering
• Controller building
• Machine tool manufacture
• Installation systems
• Electrical/electronics industry and the skilled trades.
• Automotive
• Water/wastewater
• F&B
Several CPUs of different performance levels and a comprehensive module range with many convenient functions are available. Failsafe CPUs facilitate use in failsafe applications. The modular design allows users to use only the modules they require for their applications. In the case of task expansions, the controller can be upgraded at any time by means of additional modules:
High industrial strength thanks to high electromagnetic compatibility and high resistance to shock and vibration enable universal use of the SIMATIC S7-1500.
Product Ranges
Standard CPUs
Features |
CPU |
CPU |
CPU |
CPU |
CPU |
CPU |
Work |
150 |
300 |
500 |
1 |
2 |
4 |
Work |
1 |
1.5 |
3 |
5 |
8 |
20 |
Load |
Plug-in |
Plug-in |
Plug-in |
Plug-in |
Plug-in |
Plug-in |
Display |
3.45 |
3.45 |
6.1 |
6.1 |
6.1 |
6.1 |
Command |
||||||
<![if !supportLists]>· <![endif]>Bit operations |
0.06 |
0.04 |
0.03 |
0.01 |
0.002 |
0.001 |
<![if !supportLists]>· <![endif]>Word operations |
0.072 |
0.048 |
0.036 |
0.012 |
0.003 |
0.002 |
<![if !supportLists]>· <![endif]>Fixed-point operations |
0.096 |
0.064 |
0.048 |
0.016 |
0.003 |
0.002 |
<![if !supportLists]>· <![endif]>Floating-point operations |
0.384 |
0.256 |
0.192 |
0.064 |
0.012 |
0.006 |
Bit |
||||||
S7 |
2048 |
2048 |
2048 |
2048 |
2048 |
2048 |
IEC |
arbitrary |
|||||
IEC |
arbitrary |
|||||
Bit |
16 |
16 |
16 |
16 |
16 |
16 |
I/O |
||||||
Inputs |
32 |
|||||
Outputs |
32 |
|||||
Motion |
||||||
No. |
Up |
Up |
Up |
Up |
Up |
Up |
Communication |
||||||
PtP |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
PROFINET |
Yes |
Yes |
1 |
1 |
1 |
2 |
PROFINET |
1 |
1 |
1 |
1 |
1 |
1 |
PROFIBUS |
Yes |
Yes |
Yes |
1 |
1 |
1 |
Web |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Fail-sage
CPUs
Features |
CPU 1511F-1 |
CPU 1513F-1 |
CPU 1515F-2 |
CPU 1516F-3 |
CPU 1517F-3 |
CPU 1518F-4 |
Work |
225 |
450 |
750 |
1.5 |
1.5 |
6 |
Work |
1 |
1.5 |
3 |
5 |
5 |
20 |
Load |
Plug-in |
Plug-in |
Plug-in |
Plug-in |
Plug-in |
Plug-in |
Display |
3.45 |
3.45 |
6.1 |
6.1 |
6.1 |
6.1 |
Command |
||||||
<![if !supportLists]>· <![endif]>Bit operations |
0.06 |
0.04 |
0.03 |
0.01 |
0.002 |
0.001 |
<![if !supportLists]>· <![endif]>Word operations |
0.072 |
0.048 |
0.036 |
0.012 |
0.003 |
0.002 |
<![if !supportLists]>· <![endif]>Fixed-point operations |
0.096 |
0.064 |
0.048 |
0.016 |
0.003 |
0.002 |
<![if !supportLists]>· <![endif]>Floating-point operations |
0.384 |
0.256 |
0.192 |
0.064 |
0.012 |
0.006 |
Integral |
||||||
PROFINET |
1 |
1 |
1 |
1 |
1 |
1 |
PROFINET |
– |
– |
1 |
1 |
1 |
2 |
PROFIBUS |
– |
– |
– |
1 |
1 |
1 |
Standards, |
SIL PL |
SIL PL |
SIL PL |
SIL PL |
SIL PL |
SIL PL |